FTTx SINGLE BAY PRODUCT RANGE

, ,

WITH ELECTRICAL INSTALLATION

Outdoor C-TYPE FTTx Cabinet With Single Door, Fan(s), 800W

  • G600/275 or optional Stainless Steel 1.4003 Construction
  • Removable door(s), rear panel (when installed), roof &
    base plate
  • Double-wall with internal insulation panel option
  • IP 55 or NEMA 12
Image shows plinth with cab above

CONTENTS SUPPLIED

 
ITEM DESCRIPTION QTY
1 Double skin body with internal ceiling plate (including lifting eyes) 1
2 Roof Panel, hinged for ease of access to climate control fans 2
3 Double skin removable front door; *3-point lock, swivel handle with CAM lock as standard (Options: DIN profile half cylinder, Padlock staple/hasp, and Electronic locking), door opening angle 165 °, door stay allows 120 °; door hinges left + right hand options 1
4 Double skin rear door* or panel option (see part code above) 1
5 Base/Plinth (S143803x) mounted to base of cab as standard (supplied loose on request) 1
6 Depth members for 19 “/ metric panel/slide mounts fitted as standard 4
7 19” panel mounting posts (2 pairs) fitted as standard; Optional ETSI, backboard & mixture of 19”/ETSI mounting arrangements on request 1
8 Earth/grounding kit, fitted 1
9 Radial fan (2 pieces), 360 mÂł/h, 53 dB (A), max. 48vdc, multiple thermos sensors; Filter media G4 to front door/ & rear panel/door as part code shown above 1
10 Optional Laptop carrier (P6417501-KIT), mounted on the inside of the door 1
11 Document Wallet (CA020), mounted on the inside of the door 1
12 Electrical Installation (S143838x) mounted on 5U recess bracket; biased to front lower 19” as standard (Contact Cannon for further details of available configurations) 1

FTTx SINGLE BAY PRODUCT RANGE

PRODUCT FEATURES

  • EMC Shielding: No (OPTIONAL DESIGN ON REQUEST)
  • Thermal management forced ambient air fan(s) 1kw per fan @100% (2 installed) with optional speed control remote monitoring alarms
  • Complies With: IEC 61969-1; IEC 61969-2; IEC 61969-3; IEC 60917-1; IEC 60917-2; ETS 300119; IEC 60529; DIN EN 50178; VDE 0160; ETSI EN 300019-1-4
  • Extensive range of 19” cabinet accessories
  • Remote control & monitoring options via SNMP, MODbus 485, Dry-contacts
  • Electronic locking options

ADDITIONAL PRODUCT DETAILS

In the realm of Telecom, Security, and Transportation (Rail) applications, the demand for sophisticated outdoor electronic enclosures is paramount. Cannon Technologies has emerged as a trusted provider of outdoor cabinets designed explicitly for these critical sectors. These outdoor cabinets are meticulously crafted to shield electronic components from the rigors of extreme weather conditions and the persistent threat of vandalism, thereby ensuring the uninterrupted functionality of vital systems. With a foundation in standard construction, these cabinets offer a spectrum of configuration possibilities, both in size and function, coupled with a versatile range of cooling solutions.  

Order Codes

PART CODE *RHRH *LHLH *RHLH *LHRH *RHBP *LHBP DESCRIPTION HEIGHT WIDTH DEPTH
S143800E-218060 -RHRH -LHLH -RHLH -LHRH -RHBP -LHBP FTTx S-TYPE SINGLE BAY DOUBLE WALL INSULATED 21U 800 600
S143800E-258060 -RHRH -LHLH -RHLH -LHRH -RHBP -LHBP FTTx S-TYPE SINGLE BAY DOUBLE WALL INSULATED 25U 800 600
S143800E-308060 -RHRH -LHLH -RHLH -LHRH -RHBP -LHBP FTTx S-TYPE SINGLE BAY DOUBLE WALL INSULATED 30U 800 600
S143800E-218080 -RHRH -LHLH -RHLH -LHRH -RHBP -LHBP FTTx S-TYPE SINGLE BAY DOUBLE WALL INSULATED 21U 800 600
S143800E-258080 -RHRH -LHLH -RHLH -LHRH -RHBP -LHBP FTTx S-TYPE SINGLE BAY DOUBLE WALL INSULATED 25U 800 600
S143800E-308080 -RHRH -LHLH -RHLH -LHRH -RHBP -LHBP FTTx S-TYPE SINGLE BAY DOUBLE WALL INSULATED 30U 800 600
S143800E-2180100 -RHRH -LHLH -RHLH -LHRH -RHBP -LHBP FTTx S-TYPE SINGLE BAY DOUBLE WALL INSULATED 21U 800 1000
S143800E-2580100 -RHRH -LHLH -RHLH -LHRH -RHBP -LHBP FTTx S-TYPE SINGLE BAY DOUBLE WALL INSULATED 25U 800 1000
S143800E-3080100 -RHRH -LHLH -RHLH -LHRH -RHBP -LHBP FTTx S-TYPE SINGLE BAY DOUBLE WALL INSULATED 30U 800 1000
 

Product door layout notes:

*RH = RIGHT HAND HINGED DOOR **LH = LEFT HAND HINGED DOOR *BP = BACK PANEL (REMOVEABLE)

Example:

*RHLH = RIGHT-HAND HINGED FRONT & LEFT-HAND HINGED REAR DOOR *LHBP = LEFT HAND HINGED DOOR & BACK PANEL (REMOVEABLE)